ARTEC STUDIO COMPLEX ALLIGNMETN SERIAL NUMBER
A dialog box will open (see Figure 165) enter the serial number of your calibration rig (it appears on the board). You should conduct the calibration only after the scanner has warmed to the optimal temperature.Ĭlick Start calibration. Two indicators on the right panel can help you assess the surface quality (green stands for good results, yellow for satisfactory and red for unsatisfactory). Otherwise, repeat Steps 7–9, click Rollback or press on the scanner.

If the yellow surface has no holes and is sufficiently flat, and if the correction results meet your expectations, click Commit or press the button on the scanner. A yellow plane that corresponds to the surface you captured using the corrected calibration settings will then appear in the 3D View window (see Figure 161). Once you finish, the calculation will start. Smoothly move the scanner away from the flat surface to approach the red mark. Look for a new red mark to appear higher on the range meter. Move the scanner smoothly toward the flat surface such that the histogram peak coincides with the red mark on the range meter (see Figure 160). A red mark will appear on the range meter. Place the scanner on a desk or attach it to a tripod, keeping a distance of about 190 mm from the flat surface (see the range meter in the 3D View window).Ĭlick Start correction or press the button on the scanner. If the surface, when captured from a distance within the suggested range, fails to render as flat or contains holes, correction is worth performing.

In some cases, owing to careless handling or transportation (jolts, accidental drops or some other reason), the scanner may fail to capture surfaces properly. Every Artec scanner is delivered pre-calibrated. In general, calibration is the process of checking and adjusting a scanner’s measurements by comparing them with the standard (etalon) values. The Diagnostic Tool is a special utility that enables you to calibrate Artec 3D scanners and correct an existing calibration.
ARTEC STUDIO COMPLEX ALLIGNMETN MANUAL

Understanding How Artec Studio Applies Transformations.Rendering and Texturing Untextured Polygons.Representation of Normals and Boundaries.Notes on Scanning With Third-Party 3D Sensors.Using Photogrammetry Solution (Scan Reference).Auto-align new scans with those marked in Workspace.Base Removal: Erasing a Supporting Surface.Selecting and Preparing Objects for Scanning.Managing Artec 3D Scanners and Products.3D Scanner Activation Using Artec Installation Center.